FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)
3-34
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
b. Block the port. Refer to Block or Unblock a Port (EFCM Basic
Edition) or Block or Unblock a Port (Element Manager).
c. Clean fiber-optic connectors. Refer to Clean Fiber-Optic
Components.
d. Unblock the port. Refer to Block or Unblock a Port (EFCM Basic
Edition) or Block or Unblock a Port (Element Manager).
e. Monitor port operation for approximately five minutes.
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
9
Inspect and service host bus adapters (HBAs).
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
10
A connection is not allowed because of a switch binding or exchange
security attribute (ESA) feature mismatch. Switch binding parameters
must be compatible for both fabric elements. At the EFCM Basic
Edition interface or Element Manager, ensure switch binding is
enabled, the connection policy is compatible, and switch membership
lists are compatible for both elements.
• EFCM Basic Edition - Refer to the McDATA EFCM Basic
Edition User Manual (620-000240) for instructions.
• Element Manager - Refer to the McDATA Sphereon 4500
Fabric Switch Element Manager User Manual (620-000175) for
instructions.
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.