FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)
Maintenance Analysis Procedures
3-33
Maintenence Analysis Procedures
—Select Open Fabric 1.0 if the product is attached to
directors or switches produced by open-fabric compliant
original equipment manufacturers (OEMs).
d. Click OK or Activate.
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
6
A loopback (wrap) plug is connected to the port with no diagnostic
running. Remove the plug from the port receptacle. If directed by the
customer, connect a fiber-optic jumper cable attaching a device to the
product.
• If the port is operational with no device attached, both LEDs
adjacent to the port extinguish and the port state is No Light.
• If the port is operational with a device attached, the blue/green
LED illuminates, the amber LED extinguishes, and the port state
is Online.
Was the maintenance action successful?
NO YES
↓ The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
7
An ISL connection is not allowed because E_Port capability is
disabled. Install the full-fabric PFE key to enable E_port capability.
Refer to Install PFE Keys (Optional) (EFCM Basic Edition) or Task 16:
Configure PFE Key (Optional) (Element Manager). Exit MAP.
8
The connection timed out because of an unresponsive device or an
ISL security violation (authorization failure reject). Check port status
and clean fiber-optic components.
a. Inform the customer the port will be blocked. Ensure the system
administrator quiesces Fibre Channel frame traffic and sets
attached devices offline.