FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)

3-28
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
5
As indicated by event code 433 or 440, the CTP card failed. Replace
the switch. Exit MAP.
6
As indicated by event code 810, 811, 812, or 850, an intermittent
thermal problem may result in switch failure. Reset the product. Refer
to IML or Reset Switch for instructions.
Was the maintenance action successful?
NO YES
The product is operational. Exit MAP.
A CTP card failure is indicated. Replace the switch. Exit MAP.
MAP 0500: Port Failure or Link Incident Analysis
This MAP describes fault isolation for small form factor pluggable
(SFP) optical transceivers and Fibre Channel link incidents. The
failure indicator is:
Event code 080, 081, 083, 506, 507, 512, 514, 515, or 516 observed at
the Event Log (EFCM Basic Edition or Element Manager interface).
Event code 581, 582, 583, 584, 585, or 586 observed at the console
of an OSI server attached to the product reporting the problem.
An error message observed at the Link Incident Log (EFCM Basic
Edition or Element Manager interface).
1
Table 3-9 lists event codes, explanations, and MAP steps.
Table 3-9 MAP 500 Event Codes
Event
Code
Explanation Action
080 Unauthorized worldwide name. Go to step 2.
081 Invalid attachment. Go to step 3.
083 Port set to inactive state. Go to step 13.