FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)
Maintenance Analysis Procedures
3-17
Maintenence Analysis Procedures
5
A status icon (grey square with yellow exclamation mark) appears at
the SAN management application, indicating the management server
cannot communicate with the product because:
• The server-to-PC Internet link could not be established.
• AC power distribution for the product failed or AC power was
disconnected.
• The product CTP card failed.
Continue to the next step.
6
Ensure the product is connected to facility power. Inspect the product
for indications of being powered on, such as:
• An illuminated PWR LED (green) or ERR LED (amber).
• Illuminated LEDs adjacent to Fibre Channel ports.
• Audio emanations and airflow from cooling fans.
Is the product powered on?
YES NO
↓ A power distribution problem is indicated. Go to MAP 0100:
Power Distribution Analysis. Exit MAP.
7
At the SAN management application’s physical map, right-click the
status icon for the product reporting the problem and select Element
Manager from the pop-up menu. The Element Manager opens and
the Hardware View displays:
• A grey square appears at the alert panel.
• No product FRUs are visible.
•The Status table is yellow, the Status field displays No Link, and
the Reason field displays an error message listed in Table 3-7.