FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)

Maintenance Analysis Procedures
3-7
Maintenence Analysis Procedures
3
At the failed product, inspect the amber ERR LED and amber LEDs
associated Fibre Channel ports and FRUs.
Are any amber LEDs illuminated?
NO YES
A FRU failure, power-on self-test (POST) failure, link incident,
interswitch link (ISL) problem, fenced E_Port, or segmented
E_Port is indicated. To obtain event codes that identify the
failure, go to step 10.
4
Is the product management interface (browser PC, management
server, or OSI host console) powered on and operational?
NO YES
Go to step 7.
5
Power on the management interface platform and launch the
associated management application:
EFCM Basic Edition - Refer to Task 4: Configure Product at the
EFCM Basic Edition Interface (Optional) for instructions.
SAN management application - Refer to Task 6: Unpack,
Inspect, and Install the Management Server and Access the
Management Server Desktop for instructions.
OSI host console - Refer to documentation supplied with the
host system for instructions.
Was the maintenance action successful?
NO YES
Go to step 7.
6
Inspect the management interface for communication link failure.
Observe one of the following:
•A Page cannot be found, Unable to locate the server, HTTP
404 - file not found, or similar message (browser PC).