FW 08.01.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-330, November 2005)
3-6
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
MAP 0000: Start MAP
This MAP describes initial fault isolation beginning at the:
• Failed product.
• Browser-capable PC with Internet connectivity to the firmware-
resident Enterprise Fabric Connectivity Manager (EFCM) Basic
Edition interface.
• Rack-mount management server running storage area network
(SAN) management and Element Manager applications.
• Product-attached open systems interconnection (OSI) host
console.
1
Prior to fault isolation, acquire:
• A system configuration drawing or planning worksheet that
includes the location of the product, management interface,
other McDATA products, and device connections.
• The internet protocol (IP) address, gateway address, and subnet
mask for the product reporting the problem.
• User IDs and passwords.
Continue to the next step.
2
Ensure the product is connected to facility power. Inspect the product
for indications of being powered on, such as:
• An illuminated PWR LED (green) or ERR LED (amber).
• Illuminated LEDs adjacent to Fibre Channel ports.
• Audio emanations and airflow from cooling fans.
Is the product powered on?
YES NO
↓ A power distribution problem is indicated. Go to MAP 0100:
Power Distribution Analysis. Exit MAP.