Maintenence Analysis Procedures
300 Cooling fan propeller failed. Go to MAP 0400.
301 Cooling fan propeller failed. Go to MAP 0400.
302 Cooling fan propeller failed. Go to MAP 0400.
303 Cooling fan propeller failed. Go to MAP 0400.
304 Cooling fan propeller failed. Go to MAP 0400.
305 Cooling fan propeller failed. Go to MAP 0400.
310 Cooling fan propeller recovered. No action required.
311 Cooling fan propeller recovered. No action required.
312 Cooling fan propeller recovered. No action required.
313 Cooling fan propeller recovered. No action required.
314 Cooling fan propeller recovered. No action required.
315 Cooling fan propeller recovered. No action required.
370 Cooling fan status polling temporarily disabled. Go to MAP 0400.
400 Power-up diagnostic failure. Go to MAP 0200.
410 Switch reset. No action required.
411 Firmware fault. Go to MAP 0200.
412 CTP watchdog timer reset. Go to Collect Maintenance Data. (EFCM Basic) or
Collect Maintenance Data (Element Manager).
421 Firmware download complete. No action required.
423 CTP firmware download initiated. No action required.
426 Multiple ECC single-bit errors occurred. Go to MAP 0400.
433 Non-recoverable Ethernet fault. Go to MAP 0400.
440 Embedded port hardware failed. Go to MAP 0400.
442 Embedded port anomaly detected. No action required.
445 ASIC detected a system anomaly. No action required.
Table 3-3 Event Codes versus Maintenance Action (Continued)
Event
Code
Explanation Action