FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
2
2-44
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Installation Tasks
Figure 2-27 COMn Properties Dialog Box
8. Configure the Port Settings parameters as follows:
— Bits per second - 115200.
— Data bits - 8.
— Parity - None.
— Stop bits - 1.
— Flow control - Hardware or None.
When the parameters are set, click OK. The Sphereon 4500 -
HyperTerminal window displays.
9. At the > prompt, type the user-level password (the default is
password) and press Enter. The password is case sensitive. The
Sphereon 4500 - HyperTerminal window (Figure 2-28 on page 2-45)
displays with software and hardware version information for the
switch, and a C > prompt at the bottom of the window.