FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
1
1-24
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
General Information
• Notified of a switch problem by E-mail message, either directly or
through a system administrator at the customer site or call center.
• Assigned a service call from call center personnel upon receipt
and confirmation of a switch call-home event.
NOTE: The call-home feature is not available through the SANpilot
interface. The call-home feature may not be available if the EFCM 8.0
Lite application is installed on a customer-supplied platform.
Tools and Test Equipment
This section describes tools and test equipment that may be required
to install, test, service, and verify operation of the switch and
attached management server. These tools are supplied with the
switch or must be supplied by service personnel.
Tools Supplied with
the Switch
The following tools are supplied with the switch. Use of the tools
may be required to perform one or more installation, test, service, or
verification tasks.
• Loopback plug - An SFP multimode (shortwave laser) or
singlemode (longwave laser) loopback plug (Figure 1-12) is
required to perform port loopback diagnostic tests. One loopback
plug is shipped with the switch, depending on the type of port
transceivers installed. Both plugs are shipped if shortwave laser
and longwave laser transceivers are installed.
Figure 1-12 Loopback Plug