FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Consolidating EFC Servers
D-5
Consolidating Management Servers
This procedure provides instructions to consolidate multiple
management servers into a single environment. The procedure is
divided into steps that are:
Common for all configurations.
Unique to the private LAN configuration.
Unique to the public LAN and corporate intranet configuration.
Common Steps for
All Configurations
Perform the following steps for the switch configurations shown in
Figure D-1 on page D-2 and Figure D-2 on page D-2:
1. Designate one rack-mount server as the management server
(as directed by the customer’s network administrator) and the
remaining servers as client backups.
2. Ensure each rack-mount server has a unique IP address
configured for the right RJ-45 adapter (LAN 2) at the rear of the
server. Repeat this step for the management server and all client
servers.
a. At the server’s LCD panel, press ENTER. The Welcome!! or
operational information message changes to the following
(Figure D-4):
Figure D-4 LCD Panel (Password Entry)
b. Using the button to increment a digit, the button to
decrement a digit, the button to move the cursor left, and
the button to move the cursor right, input the default or
changed password, and press ENTER. The LAN 1 Setting??
message appears at the LCD panel.
c. Press the button. The LAN 2 Setting?? message appears at
the LCD panel. Press ENTER and the following message
appears (Figure D-5 on page D-6) with the default IP address
of 10.1.1.1.
Input Password:
0****