FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

B-34
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Event Code: 445
Message: ASIC detected a system anomaly.
Severity: Informational.
Explanation: The application-specific integrated chip (ASIC) detected a deviation in the normal operating mode or operating
status of the switch.
Action: No action required. An additional event code is generated if this incident exceeds an error threshold that results in
a system event.
Event Data: Byte 0 = embedded port number. Byte 12 = detecting port.
Byte 1 = anomaly reason code. Byte 13 = connected port.
Bytes 4 - 7 = elapsed millisecond tick count. Bytes 16 and 17 = high-availability error callout #3.
Bytes 8 and 9 = high-availability error callout #1. Bytes 18 and 19 = high-availability error callout #4.
Bytes 10 and 11 = high-availability error callout #2.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 453
Message: New feature key installed.
Severity: Informational.
Explanation: This event occurs when a new feature key is installed from the management server or SANpilot interface. The
switch performs an IPL when the feature key is enabled. Event data indicates which feature(s) are installed.
Action: No action required.
Event Data: Byte 0 = feature description as follows: 00 - 04 = Flexport Technology, 06 = Open-system management server.
Byte 1 = feature description as follows: 06 = SANtegrity binding, 07 = OpenTrunking.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED