FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Event Code Tables
B-25
Event Code: 304
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Five cooling fans (out of six) failed or are rotating at insufficient angular velocity. The remaining fan is operational.
The amber LED illuminates at the rear of both power supply assemblies.
Action: Replace both power supply assemblies.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 305
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: All six cooling fans failed or are rotating at insufficient angular velocity. The amber LED illuminates at the rear of
both power supply assemblies.
Action: Replace both power supply assemblies.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔