FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
B-24
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Event Code: 302
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Three cooling fans (out of six) failed or are rotating at insufficient angular velocity. The remaining fans are
operational. The amber LED illuminates at the rear of the power supply assembly (or assemblies) associated with
the failed fans.
Action: Replace the power supply assembly (or assemblies) containing the indicated fan modules.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 303
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Four cooling fans (out of six) failed or are rotating at insufficient angular velocity. The remaining fans are
operational. The amber LED illuminates at the rear of both power supply assemblies.
Action: Replace both power supply assemblies.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers (0 through 5 inclusive).
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔