FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
B-20
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Power Supply Events (200 through 299)
Event Code: 200
Message: Power supply AC voltage failure.
Severity: Major.
Explanation: AC input to the power supply is disconnected or AC circuitry in the power supply failed. The event only occurs
when two power supplies are installed. The second power supply assumes the full operating load for the switch.
Action: Ensure the power supply is connected to facility AC power and verify operation of the facility power source. If the
AC voltage does not recover (indicated by event code 203), replace the failed power supply. Perform the data
collection procedure and return the CD and failed power supply to McDATA support personnel.
Event Data: No supplementary data included with the event.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 201
Message: Power supply DC voltage failure.
Severity: Major.
Explanation: DC circuitry in the power supply failed. The event only occurs when two power supplies are installed. The second
power supply assumes the full operating load for the switch.
Action: Replace the failed power supply. Perform the data collection procedure and return the CD and failed power
supply to McDATA support personnel.
Event Data: No supplementary data included with the event.
Distribution: Switch Management Server Host
SANpilot
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔