FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Messages
A-25
Description Device WWNs were removed from the switch membership list
(SANtegrity binding feature), but one or more of the devices still has
security controlled by port binding.
Action Verify the security level for each device is specified as required by
reviewing the Bound WWN list at the Configure Ports dialog box.
Message System diagnostics cannot run. The operational status is invalid.
Description System diagnostics cannot run on a switch with failed ports.
Action Replace failed port transceivers.
T
Message The add firmware process has been aborted.
Description A user ended the add firmware process.
Action Information message - no action required.
Message The data collection process failed.
Description An error occurred in the data collection process.
Action Contact support personnel and report the problem.
Message The data collection process has been aborted.
Description A user ended the data collection process.
Action Information message - no action required.
Message The default zone must be disabled to configure.
Description A user attempted to change the switch interoperability mode to Open
Fabric Mode with the default zone enabled.
Action Disable the default zone and repeat the operation.