FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Messages
A-23
Description A user disabled port binding for attached devices, but one or more of
the devices is controlled by fabric binding.
Action Review the switch binding membership list to determine if devices
should or should not be included.
Message Port diagnostics cannot be performed on an inactive port.
Description This message displays when port diagnostics are performed on an
inactive port.
Action Perform diagnostics on an active port.
Message Port speeds cannot be configured at a higher rate than the switch
speed.
Description An attempt was made to configure a port to 2.125 Gbps with the
switch speed set to 1.0625 Gbps.
Action Set the port speed to 1.0625 Gbps at the Configure Ports dialog box.
Message Preferred Paths can not be enabled until the Domain ID is set to
Insistent. Disable Preferred Paths, then configure Switch
Parameters.
Description If the switch’s domain ID has not been set to Insistent, the user is not
allowed to activate the Preferred Path configuration with the Enable
Preferred Paths check box selected.
Action Close the Configure Preferred Paths dialog box and select the Configure
menu, then Operating Parameters, then Switch Parameters. On the
Configure Switch Parameters dialog box, select the Insistent check box.
R
Message R_A_TOV must be greater than E_D_TOV.
Description The R_A_TOV value must be greater than the E_D_TOV value.
Action Change a value so R_A_TOV exceeds E_D_TOV.