FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

A-20
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
L
Message Link dropped.
Description The switch-to-management server link was dropped.
Action Wait approximately 30 seconds for the link to establish and retry the
operation. If the condition persists, contact support personnel.
Message Log is currently in use.
Description The selected log is in use by another Element Manager instance.
Action Retry the operation. If the condition persists, contact support
personnel and report the problem.
Message Loopback plug(s) must be installed on ports being diagnosed. Press
NEXT to continue.
Description An optical loopback plug must be installed in a Fibre Channel port
prior to performing an external loopback diagnostic test.
Action Ensure an optical loopback plug is installed in the port, then restart
the test.
M
Message Maximum number of versions already installed.
Description The maximum number of firmware versions was reached.
Action Delete a firmware version before adding a new firmware version.
Message McDATA SANtegrity binding feature not installed. Please contact
your sales representative.
Description A user selected Switch Binding from the Configure menu. This
selection is not supported because the SANtegrity binding feature is
not installed.
Action Install the optional SANtegrity binding feature key through the
Configure Feature Key dialog box before enabling switch binding.