FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Messages
A-7
Message Cannot run diagnostics on a port that is failed.
Description Port diagnostics cannot be performed on a failed port.
Action Run diagnostics only on an operational port.
Message Cannot run diagnostics on an active E_Port.
Description Port diagnostics cannot be performed on a configured and active
expansion port (E_Port).
Action Run diagnostics only on an inactive E-port.
Message Cannot run diagnostics. The port is not installed.
Description Port diagnostics cannot be performed if the port transceiver is not
installed.
Action Install an optical transceiver or run diagnostics only on a port with an
installed transceiver.
Message Cannot save port configuration.
Description The port configuration cannot be saved. The link is down or busy.
Action Retry the operation later. If the condition persists, contact support
personnel and report the problem.
Message Cannot save SNMP configuration.
Description The SNMP configuration cannot be saved. The link is down or busy.
Action Retry the operation later. If the condition persists, contact support
personnel and report the problem.
Message Cannot set all ports to 1 Gbps due to port speed restriction on some
ports.
Description This message displays if all ports are set to 1 Gb/sec through the
Configure Ports dialog box and some port transceivers do not support
this transceiver speed.