FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

FRU Removal and Replacement
5-9
a. While supporting the power supply with one hand, insert it
into the switch chassis.
b. Firmly push the power supply into the chassis. Rotate the
finger handles 90 degrees inward to seat the power supply and
engage the connector pins. Ensure the faceplate is flush with
the chassis cutout.
4. Connect the AC power cord to the power supply and to a facility
power source.
5. Wait several seconds, then inspect the power supply to ensure
the amber LED is extinguished. If the LED is illuminated, go to
MAP 0000: Start MAP on page 3-6 to isolate the problem.
6. Perform one of the following to inspect the Event Log:
If at a web browser connected to the SANpilot interface, click
the Log tab at the Monitor panel. The Event Log displays.
Ensure the following event codes appear. If the event codes do
not appear, go to MAP 0000: Start MAP on page 3-6 to isolate
the problem.
207 - Power supply installed.
313 - A cooling fan propeller has recovered (first fan).
314 - A cooling fan propeller has recovered (second fan).
315 - A cooling fan propeller has recovered (third fan).
203 - Power supply AC voltage recovery.
If at the management server, open the Hardware View, click
Logs, and select Event Log. The Event Log displays. Ensure
the following event codes appear. If the event codes do not
appear, go to MAP 0000: Start MAP on page 3-6 to isolate
the problem.
207 - Power supply installed.
313 - A cooling fan propeller has recovered (first fan).
314 - A cooling fan propeller has recovered (second fan).
315 - A cooling fan propeller has recovered (third fan).
203 - Power supply AC voltage recovery.