FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
FRU Removal and Replacement
5-7
— If the switch is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet front door as directed by
the customer representative.
2. Identify the defective power supply from:
— The illuminated amber LED on the FRU.
— At the SANpilot interface, failure information associated with
the power supply at the FRU Properties page of the View panel.
— At the management server (Sphereon 4500 Element Manager
application), failure information associated with the power
supply at the Hardware View or FRU List View.
3. Disconnect the AC power cord from the power supply.
DANGER
Disconnect the power cords.
4. Disengage and remove the power supply as follows:
a. Disengage the locking mechanism by rotating both finger
handles outward by 90 degrees as shown in part (A) of
Figure 5-2.
Figure 5-2 Redundant Power Supply Removal and Replacement