FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

5-4
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Figure 5-1
SFP Optical Transceiver Removal and Replacement
7. Perform one of the following to inspect the Event Log:
— If at a web browser connected to the SANpilot interface, click
the Log tab at the Monitor panel. The Event Log displays. An
event code 513 (SFP optics hot-removal completed) appears.
— If at the management server, open the Hardware View, click
Logs, and select Event Log. The Event Log displays. An event
code 513 (SFP optics hot-removal completed) appears.
Replacement To replace an SFP optical transceiver:
1. Remove the replacement transceiver from its packaging.
2. Insert the transceiver into the port receptacle, then engage the
locking mechanism by rotating the wire locking bale up or down
90 degrees as shown in Figure 5-1.
3. Perform an external loopback test on the port. Refer to Perform
Port Diagnostic Loopback Tests on page 4-38 for instructions. If the
test fails, go to MAP 0000: Start MAP on page 3-6 to isolate the
problem.
4. Reconnect the fiber-optic jumper cable:
a. Remove the protective cap from the cable connector and the
protective plug from the port’s optical transceiver. Store the cap
and plug in a suitable location for safekeeping.
b. Clean the jumper cable and transceiver connectors. Refer to
Clean Fiber-Optic Components on page 4-54 for instructions.