FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
4-48
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
5. At the Save Data Collection dialog box, select the compact disc
drive (D:\) from the Look in drop-down menu, type a descriptive
name for the collected maintenance data in the File name field,
then click Save.
6. The Data Collection dialog box (Figure 4-31) displays with a
progress bar that shows percent completion of the data collection
process. When the process reaches 100%, the Cancel button
changes to a Close Button.
Figure 4-31 Data Collection Dialog Box
7. Click Close to close the dialog box.
8. Remove the CD with the newly-collected maintenance data from
the management server’s CD-RW drive. Return the CD with the
failed FRU to McDATA for failure analysis.
9. To ensure the backup application operates normally, replace the
original backup CD in the management server’s CD-RW drive.
Set the Switch Online or Offline
This section describes procedures to set the switch online or offline.
These operating states are described as follows:
• Online - When the switch is set online, an attached device can log
in to the switch if the port is not blocked. Attached devices can
communicate with each other if they are configured in the same
zone.
• Offline - When the switch is set offline, all switch ports are set
offline. The switch transmits the offline sequence (OLS) to
attached devices, and the devices cannot log in to the switch.