FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
4-42
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Figure 4-26
Port Diagnostics Dialog Box
5. Type the port number to be tested or select all ports at the Port
Select area of the dialog box.
6. At the Diagnostics Test list box, select the Internal Loop option.
7. Click Next. The message Press START TEST to begin diagnostics
appears, and the Next button changes to a Start Test button.
8. Click Start Test. The test begins and:
a. The Start Test button changes to a Stop Test button.
b. The message Port xx: TEST RUNNING appears.
c. A red progress bar (indicating percent completion) travels
from left to right across the Completion Status field.
NOTE: Click Stop Test at any time to abort the loopback test.
9. When the test completes, results appear as Port xx: Passed! or
Port xx: Failed! in the message area of the dialog box.
10. When finished, click Cancel to close the Port Diagnostics dialog
box.