FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
4-18
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
The log displays a history of FRU removals and replacements
(insertions) for the switch. The information is useful to maintenance
personnel for fault isolation and repair verification. The log consists
of the following columns:
• Date/Time - Date and time the FRU was inserted or removed.
• FRU - Acronym representing the FRU type. FRU acronyms are:
— CTP - Control processor card. The CTP card is not a FRU. A
failed CTP card requires replacement of the switch.
— PWR - Power supply.
Three cooling fans are integrated in each power supply.
Cooling fans are not FRUs. A failed cooling fan requires
replacement of the power supply.
• Position - Number representing the FRU chassis position. The
chassis (slot) position for a nonredundant CTP card is 0. Chassis
slots for redundant power supplies are 0 and 1.
• Action - Action performed (Inserted or Removed).
• Part Number - Part number of the inserted or removed FRU.
• Serial Number - Serial number of the inserted or removed FRU.
Link Incident Log To open the Link Incident Log, select the Link Incident Log option from
the Logs menu at the Hardware View, Port List View, Node List View,
Performance View, or FRU List View. The log displays (Figure 4-15).
Figure 4-15 Link Incident Log
The log displays a history of Fibre Channel link incidents (with
associated port numbers) for the switch. The information is useful to
maintenance personnel for isolating port problems and repair
verification. The log consists of the following columns: