FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
4-17
The log consists of the following columns:
Date/Time - Date and time the event occurred.
Event - Three-digit code that describes the event. Event codes are
listed and described in Appendix B: Event Code Tables on page B-1.
Description - Brief description of the event.
Severity - Severity of the event (Informational, Minor, Major, or
Fatal).
FRU-Position - Acronym representing the FRU type, followed by
a number representing the FRU chassis position. Acronyms are:
CTP - Control processor (CTP) card. The chassis slot is 0.
The CTP card is not a FRU.
PWR - Power supply. Chassis slots for redundant power
supplies are 0 and 1.
Three cooling fans are integrated in each power supply.
Cooling fans are not FRUs. A failed cooling fan requires
replacement of the power supply.
Event Data - Up to 32 bytes of supplementary information
(if available) in hexadecimal format. Event data is described in
Appendix B: Event Code Tables on page B-1.
To ensure recently-created events appear in the log, periodically
refresh the log display. This is important when inspecting the log to
verify a repair procedure. To refresh the log, click Refresh.
Hardware Log To open the Hardware Log, select the Hardware Log option from the
Logs menu at the Hardware View, Port List View, Node List View,
Performance View, or FRU List View. The log displays (Figure 4-14).
Figure 4-14 Hardware Log