FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-117
• CPU temperature.
• Hard disk capacity.
• Virtual and physical memory capacity.
d. After successful POST completion, the LCD panel displays a
Welcome!! message, then continuously cycles through and
displays server operational information.
e. After rebooting the server at the LCD panel, log on to the
management server’s Windows 2000 desktop through a LAN
connection to a browser-capable PC. Refer to Access the
Management Server Desktop on page 2-55 for instructions.The
SAN management application starts and the SANavigator Log In
or EFCM Log In dialog box displays (Figure 3-48 on
page 3-115).
f. At the SANavigator Log In or EFCM Log In dialog box, type a
user ID and password (obtained in MAP 0000: Start MAP, and
both are case sensitive), and click Login. The SAN management
application opens and the SANavigator or EFCM main window
displays (Figure 3-9 on page 3-17).
Did the main window display and does the SAN management
application appear operational?
NO YES
↓ The server appears operational. Exit MAP.
11
Re-install the SAN management application. Refer to Install or
Upgrade Software on page 4-87 for instructions.
Did the SAN management application install and open successfully?
NO YES
↓ The server appears operational. Exit MAP.