FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-114
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
4. Ignore the message. After ten seconds, the server performs
the boot sequence from BIOS. During the boot sequence, the
server performs additional POSTs and displays the following
operational information at the LCD panel:
•Host name.
System date and time.
LAN 1 and LAN 2 IP addresses.
Fan 1, fan 2, fan 3, and fan 4 rotational speed.
CPU temperature.
Hard disk capacity.
Virtual and physical memory capacity.
d. After successful POST completion, the LCD panel displays a
Welcome!! message, then continuously cycles through and
displays server operational information.
Did POSTs detect a problem?
NO YES
A computer hardware problem exists. Refer to the supporting
documentation shipped with the server for instructions on
resolving the problem. Exit MAP.
7
After rebooting the server at the LCD panel, log on to the
management server’s Windows 2000 desktop through a LAN
connection to a browser-capable PC. Refer to Access the
Management Server Desktop on page 2-55 for instructions.The SAN
management application starts and the SANavigator Log In or EFCM
Log In dialog box displays (Figure 3-48 on page 3-115).