FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-111
3
Are you performing fault isolation at one of the following servers?
The rack-mount management server running the Windows 2000
Professional operating system.
A customer-supplied server running the client SAN management
application and a Windows-based operating system (Windows
95, Windows 98, Windows 2000, Windows XP, or Windows
NT 4.0).
A customer-supplied server running the EFCM Lite application
and a Windows-based operating system.
YES NO
Analysis for the server failure is not described in this MAP.
Contact the next level of support. Exit MAP.
4
At the server, close the SAN management or EFCM Lite application.
a. Select Shutdown from the SAN menu. A SANavigator or EFCM
Message dialog box displays (Figure 3-44).
Figure 3-44 SANavigator or EFCM Message Dialog Box
b. Click Yes to close the SAN management application.
c. Close any other applications.
Continue to the next step.
5
Inspect the available random access memory (RAM). The server
must have a minimum of 128 megabytes (MB) of memory to run the
Windows-based operating system and SAN management application.