FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-108
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Increase the ISL link speed between the switches reporting the
problem (from 1 Gbps to 2 Gbps).
Reroute Fibre Channel traffic by moving device connections to a
less-congested region of the fabric.
Did the corrective action solve the problem and relieve the reported
low BB_Credit condition?
NO YES
The ISL appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
25
A 150 event code indicates a zone merge process failed during ISL
initialization. Either an incompatible zone set was detected or a
problem occurred during delivery of a zone merge frame. This event
code always precedes a 070 event code, and represents the reply of
an adjacent fabric element in response to a zone merge frame.
Obtain supplementary event data for each 150 event code.
a. At the Hardware View (Figure 3-10 on page 3-20), click Logs
and select Event Log. The Event Log displays.
b. Examine the first 12 bytes (0 through 11) of event data.
c. Bytes 0 through 3 specify the E_Port number (00 through 23)
reporting the problem. Bytes 8 through 11 specify the failure
reason as specified in Table 3-17 on page 3-108.
Table 3-17 Bytes 8 through 11 Failure Reasons and Actions
Bytes 8 - 11 Failure Reason Action
01 Invalid data length. Go to step 26.
08 Invalid zone set format. Go to step 26.
09 Invalid data. Go to step 27.
0A Cannot merge. Go to step 27.
F0 Retry limit reached. Go to step 26.
F1 Invalid response length. Go to step 26.
F2 Invalid response code. Go to step 26.