FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
3-98
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
11
As indicated by an event code 061, a minor error occurred that
caused the Fabric Controller database to be re-initialized to an empty
state and fail CRC validation. As a result, the switch briefly lost
interswitch link capability.
All interswitch links resume operation after CTP reset. Perform the
data collection procedure and return the CD to McDATA for analysis.
Exit MAP.
12
As indicated by an event code 062, the Fabric Controller software
detected a path to another fabric element (director or switch) in a
multiswitch fabric that traverses more than three interswitch links
(hops). Fibre Channel frames may persist in the fabric longer than
timeout values allow.
Advise the customer of the problem and work with the system
administrator to reconfigure the fabric so the path between any two
fabric elements does not traverse more than three hops.
Did fabric reconfiguration solve the problem?
NO YES
↓ The switch and multiswitch fabric appear operational.
Exit MAP.
Contact the next level of support. Exit MAP.
13
As indicated by an event code 063, the Fabric Controller software
detected an:
• Intrepid 6064 Director in a multiswitch fabric that has more than
48 ISLs attached.
• Other fabric element (other than an Intrepid 6140 Director) in a
multiswitch fabric that has more than 32 ISLs attached.
Fibre Channel frames may be lost or routed in loops because of
potential fabric routing problems. Advise the customer of the problem
and work with the system administrator to reconfigure the fabric so
that no director or switch elements have more than the proscribed
number of ISLs.