FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-97
9
A minor error occurred that caused the Fabric Services database to
be re-initialized to an empty state. As a result, a disruptive fabric
logout and login occurred for all attached devices. The following list
explains the error:
• Event code 011 - The Login Server database failed cyclic
redundancy check (CRC) validation.
• Event code 021 - The Name Server database failed CRC
validation.
All attached devices resume operation after fabric login. Perform the
data collection procedure and return the CD to McDATA for analysis.
Exit MAP.
10
A minor error occurred that caused the Management Server database
to be re-initialized to an empty state. As a result, a disruptive server
logout and login occurred for all attached devices. The following list
explains the error:
• Event code 051 - The Management Server database failed CRC
validation.
• Event code 052 - An internal operating error was detected by
the Management Server subsystem.
All attached devices resume operation after Management Server
login. Perform the data collection procedure and return the CD to
McDATA for analysis. Exit MAP.
Table 3-15 Port Segmentation Reasons and Actions (Management
Server)
Segmentation Reason Action
Incompatible operating parameters. Go to step 15.
Duplicate domain ID. Go to step 16.
Incompatible zoning configurations. Go to step 17.
Build fabric protocol error. Go to step 18.
No principal switch. Go to step 20.
No response from attached switch (hello timeout). Go to step 21.