FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-95
3
Is fault isolation being performed through the SANpilot interface?
YES NO
Fault isolation is being performed at the management server
or customer-supplied server. Go to step 6.
4
Does the SANpilot interface appear operational?
YES NO
Analysis for an Ethernet link, AC power distribution, or CTP
failure is not described in this MAP. Go to MAP 0000: Start
MAP on page 3-6. If this is the second time at this step,
contact the next level of support. Exit MAP.
5
Inspect the Fibre Channel port segmentation reason at the SANpilot
interface.
a. At the View panel, click the Port Properties tab. The View panel
(Port Properties tab) displays.
b. Click the port number (0 through 23) of the segmented port.
c. Inspect the Reason field for the selected port.
Is the Reason field blank or does it display an N/A message?
NO YES
The switch ISL appears operational. Exit MAP.
The Reason field displays a segmentation reason message.
Table 3-14 lists the reasons and associated steps that describe fault
isolation procedures.
Table 3-14 Port Segmentation Reasons and Actions (SANpilot)
Segmentation Reason Action
Incompatible operating parameters. Go to step 15.
Duplicate domain ID. Go to step 16.
Incompatible zoning configurations. Go to step 17.