FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-93
39
The attached device is causing the recurrent link incident. Notify the
customer of the problem and have the system administrator:
a. Inspect and verify operation of the attached device.
b. Repair the attached device if a failure is indicated.
c. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
The attached device, Fibre Channel link, and switch appear
operational. Exit MAP.
Contact the next level of support. Exit MAP.
40
The switch port reporting the problem is causing the recurrent link
incident. The recurring link incident indicates port degradation and a
possible pending failure. Go to step 6.
MAP 0700: Fabric, ISL, and Segmented Port Problem
Determination
This MAP describes isolation of fabric logout, interswitch link (ISL),
and E_Port segmentation problems. Failure indicators include:
An event code recorded at the SANpilot event log or Sphereon
4500 Event Log (management server).
A segmentation reason associated with a Fibre Channel port at
the SANpilot interface.
A yellow triangle (attention indicator) appears adjacent to a port
graphic at the alert panel of the Hardware View.
A link incident message recorded in the Link Incident Log or Port
Properties dialog box.