FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-92
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
36
Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
The Fibre Channel link and switch appear operational.
Exit MAP.
37
Clean fiber-optic connectors on the jumper cable.
a. Notify the customer the port will be blocked. Ensure the
customer’s system administrator quiesces Fibre Channel frame
traffic through the port and sets the attached device offline.
b. Block the port. Refer to Block or Unblock a Port on page 4-51.
c. Disconnect both ends of the fiber-optic cable.
d. Clean the fiber-optic connectors. Refer to Clean Fiber-Optic
Components on page 4-54.
e. Reconnect the fiber-optic cable.
f. Unblock the port. Refer to Block or Unblock a Port on page 4-51.
g. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES NO
The Fibre Channel link and switch appear operational.
Exit MAP.
38
Disconnect the fiber-optic jumper cable from the switch port and
connect the cable to a spare port.
Is a link incident reported at the new port?
YES NO
Go to step 40.