FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-85
Figure 3-35 Configure Fabric Parameters Dialog Box
c. Select McDATA Fabric 1.0 or Open Fabric 1.0 from the Interop
Mode list box.
— Select the McDATA Fabric 1.0 option if the switch is
fabric-attached only to other McDATA directors or switches
that are also operating in McDATA Fabric 1.0 mode.
— Select the Open Fabric 1.0 option if the switch is
fabric-attached to directors or switches produced by other
original equipment manufacturers (OEMs) that are
open-fabric compliant.
d. Click Activate to save the selection and close the window.
Did configuring the operating mode solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
25
A loopback (wrap) plug appears to be connected to the port and
there is no diagnostic test running. Is a loopback plug in the port
receptacle?
YES NO
↓ Contact the next level of support. Exit MAP.