FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
3-82
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Was port beaconing enabled because port failure or degradation was
suspected?
YES NO
↓ The switch appears operational. Exit MAP.
Go to step 1.
21
As indicated by a message or event code 080, the eight-byte
(16-digit) worldwide name (WWN) entered to configure port binding is
not valid or a nickname was used that is not configured for the
attached device in the Element Manager application.
From the Hardware View (Figure 3-10 on page 3-20), click Node List.
Note the Port WWN column. This is the WWN assigned to the port or
Fibre Channel interface installed on the attached device.
• If a nickname is not assigned to the WWN, the WWN is prefixed
by the device manufacturer’s name.
• If a nickname is assigned to the WWN, the nickname appears in
place of the WWN.
The bound WWN must be entered in the form of a raw WWN format
(XX:XX:XX:XX:XX:XX:XX:XX) or must be a valid nickname. Ensure
a valid WWN or nickname is entered.
Did configuring the WWN or nickname solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
22
As indicated by a message or event code 081, a port has an invalid
attachment. The information in the Port Properties dialog box
specifies the reason as listed in Table 3-12.
Table 3-12 Invalid Attachment Reasons and Actions
Reason Action
Unknown Contact the next level of support.
ISL connection not allowed. Go to step 23.
Incompatible switch. Go to step 24.