FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-80
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
c. Table 3- 11 lists LED and port operational state combinations and
associated MAP 0600 (or other) steps that describe fault
isolation procedures.
17
A link incident may have occurred, but the LIN alerts option is not
enabled for the port and the attention indicator does not appear.
At the Hardware View (Figure 3-10 on page 3-20), click Logs and
select Link Incident Log. The Link Incident Log displays. If a link
incident occurred, the affected port number is listed with one of the
following messages.
Link interface incident - implicit incident.
Link interface incident - bit-error threshold exceeded.
Link failure - loss of signal or loss of synchronization.
Link failure - not-operational primitive sequence (NOS)
received.
Link failure - primitive sequence timeout.
Link failure - invalid primitive sequence received for the
current link state.
Table 3-11 Port Operational and LED States (Management Server)
Operational State Green LED Amber LED Action
Offline Off Off Go to step 19.
Not Operational Off Off Go to step 19.
Testing Off Blinking Internal loopback test in
process. Exit MAP.
Testing On Blinking External loopback test in
process. Exit MAP.
Beaconing Off or On Blinking Go to step 20.
Invalid Attachment On Off Go to step 22.
Link Reset Off Off Go to step 33.
Link Incident Off Off Go to step 34.
Segmented E_Port On Off Go to MAP 0700.