FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-79
12
Install an SFP optical transceiver in the port receptacle. Refer to
RRP 1: SFP Optical Transceiver on page 5-2.
This procedure is concurrent and can be performed while the
switch is powered on and operational.
Verify location of the failed port.
Perform an external loopback test for the port as part of FRU
removal and replacement. Refer to Perform Port Diagnostic
Loopback Tests on page 4-38.
Exit MAP.
13
At the management server, does a blinking red and yellow diamond
(failed FRU indicator) appear adjacent to a Fibre Channel port graphic
at the Hardware View (Figure 3-10 on page 3-20)?
NO YES
A port failure is indicated. Go to step 6.
14
Did a Fibre Channel port fail a loopback test?
NO YES
Go to step 18.
15
Does a yellow triangle (attention indicator) appear adjacent to a port
graphic at the Hardware View?
YES NO
Go to step 17.
16
Inspect the port state and LED status for all ports with an attention
indicator.
a. At the Hardware View (Figure 3-10 on page 3-20), double-click
the port graphic with the attention indicator. The Port Properties
dialog box displays.
b. Inspect the Operational State field at the Port Properties dialog
box, and the emulated green and amber LEDs adjacent to the
port at the Hardware View.