FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-75
A blinking red and yellow diamond (failed FRU indicator)
appears over a port graphic or a yellow triangle (attention
indicator) appears at the alert panel of the Hardware View.
A link incident message recorded in the Link Incident Log or Port
Properties dialog box.
1
Was an event code 080, 081, 506, 507, 512, or 514 observed at the
SANpilot event log or at the Sphereon 4500 Event Log (management
server)?
NO YES
Go to step 3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the
console of an OSI server attached to the switch reporting the
problem?
YES NO
Go to step 4.
3
Table 3-9 lists event codes, brief explanations of the codes, and
associated steps that describe fault isolation procedures.
Table 3-9 MAP 600 Event Codes
Event
Code
Explanation Action
080 Unauthorized worldwide name. Go to step 21.
081 Invalid attachment. Go to step 22.
506 Fibre Channel port failure. Go to step 6.
507 Loopback diagnostics port failure. Go to step 18.
512 SFP optical transceiver nonfatal error. Go to step 6.
514 SFP optical transceiver failure. Go to step 6.
581 Implicit incident. Go to step 34.
582 Bit error threshold exceeded. Go to step 34.