FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-72
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
8
Is the green PWR LED illuminated, the amber ERR LED illuminated,
and all Fibre Channel traffic disrupted (not operational)?
NO YES
A CTP card failure is indicated. Replace the switch.
Exit MAP.
Analysis for this failure is not described in this MAP. Go to MAP 0000:
Start MAP on page 3-6. If this is the second time at this step, contact
the next level of support. Exit MAP.
9
An event code 426 (SDRAM problem), 810 (high-temperature
warning), or 811 (critically-hot temperature warning) indicates an
intermittent problem that may result in switch failure.
Is the appearance of this event code a recurring problem?
NO YES
A CTP card failure is indicated. Replace the switch.
Exit MAP.
Perform the data collection procedure and contact the next level of
support. Refer to Collect Maintenance Data on page 4-44. Exit MAP.
10
An event code 433 or 440 indicates a CTP card failure. Replace the
switch. Exit MAP.
11
Is fault isolation being performed at the SANpilot interface?
YES NO
Fault isolation is being performed at the management server
or customer-supplied server. Go to step 16.
12
Does the SANpilot interface appear operational?
NO YES
Go to step 14.