FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-71
• Perform the data collection procedure as part of FRU removal
and replacement.
ATTENTION ! Do not remove a power supply unless a replacement FRU is
immediately available. To avoid product overheating, a removed power
supply must be replaced within five minutes.
Do the fan and power supply module(s) appear to function?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
7
Inspect the switch front panel.
Is the green PWR LED illuminated and the amber ERR LED
illuminated and blinking (beaconing)?
YES NO
↓ Go to step 8.
Beaconing is enabled for the switch.
a. Consult the customer and next level of support to determine the
reason switch (unit) beaconing is enabled.
b. Disable unit beaconing.
1. At the Hardware View (Figure 3-10 on page 3-20), right-click
the front bezel graphic (away from a FRU). A pop-up menu
appears.
2. Click the Enable Unit Beaconing option. The check mark
disappears from the box adjacent to the option, and unit
beaconing is disabled.
Was switch beaconing enabled because a FRU failure or degradation
was suspected?
NO YES
↓ Go to step 1.
The switch appears operational. Exit MAP.