FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-69
1
Was an event code 300, 301, 302, 303, 304, 305, 426, 433, 440, 810,
or 811 observed at the SANpilot event log or at the Sphereon 4500
Event Log?
YES NO
↓ Go to step 3.
2
Table 3-8 lists event codes, brief explanations of the codes, and
associated steps that describe fault isolation procedures.
3
Is fault isolation being performed at the switch?
YES NO
↓ Fault isolation is being performed at the SANpilot interface,
management server, or customer-supplied server. Go to
step 11.
Table 3-8 MAP 500 Event Codes
Event
Code
Explanation Action
300 Cooling fan propeller failed. Go to step 6.
301 Cooling fan propeller failed. Go to step 6.
302 Cooling fan propeller failed. Go to step 6.
303 Cooling fan propeller failed. Go to step 6.
304 Cooling fan propeller failed. Go to step 6.
305 Cooling fan propeller failed. Go to step 6.
426 Multiple ECC single-bit errors occurred. Go to step 9.
433 Non-recoverable Ethernet fault. Go to step 10.
440 Embedded port hardware failed. Go to step 10.
810 High temperature warning (CTP thermal sensor). Go to step 9.
811 Critically hot temperature warning (CTP thermal
sensor).
Go to step 9.