FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

Diagnostics
3-59
21
An instance of the SAN management application is open at another
management server or customer-supplied server and is
communicating with the switch (duplicate session). Notify the
customer and either:
Power off the management server or customer-supplied server
running the second instance of the application, or
Configure the management server or customer-supplied server
running the second instance of the application as a client
workstation.
Does the customer want the second management server or
customer-supplied server configured as a client?
YES NO
Power off the management server or customer-supplied
server reporting the Duplicate Session communication
problem. Exit MAP.
22
Determine the internet protocol (IP) address of the management
server or customer-supplied server running the first instance of the
SAN management application.
a. After the management server powers on and successfully
completes POSTs, the LCD panel displays a Welcome!!
message, then continuously cycles through and displays the
following operational information:
—Host name.
System date and time.
LAN 1 and LAN 2 IP addresses.
Fan 1, fan 2, fan 3, and fan 4 rotational speed.
CPU temperature.
Hard disk capacity.
Virtual and physical memory capacity.