FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-49
14
Did the management server or customer-supplied server crash and
display a blue screen with the system dump file in hexadecimal format
(blue screen of death)?
YES NO
↓ The management server or customer-supplied server
appears operational. Exit MAP.
15
Attempt to clear the problem by power cycling the management
server or customer-supplied server PC. If the customer-supplied
server does not use the Windows 2000 operating system, refer to the
supporting documentation to reboot the server.
a. At the rack-mount management server, press the power ( )
button on the LCD panel to power off the server.
b. Wait approximately 30 seconds and press the power ( ) button
to power on the server and perform POSTs. During POSTs:
1. The green LCD panel illuminates.
2. The green HDD LED blinks momentarily, and processor
speed and random-access memory information display
momentarily at the LCD panel.
3. After a few seconds, the LCD panel displays the following
message pertaining to boot sequence selection (Figure 3-20
on page 3-49):
Figure 3-20 LCD Panel During Boot Sequence
4. Ignore the message. After ten seconds, the server performs
the boot sequence from BIOS. During the boot sequence, the
server performs additional POSTs and displays the following
operational information at the LCD panel:
•Host name.
• System date and time.
• LAN 1 and LAN 2 IP addresses.
Boot from LAN?
Press <Enter>