FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
3-44
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
Figure 3-17
LCD Panel During Boot Sequence
4. Ignore the message. After ten seconds, the server performs
the boot sequence from the BIOS. During the boot sequence,
the server performs additional POSTs and displays the
following operational information at the LCD panel:
•Host name.
• System date and time.
• LAN 1 and LAN 2 IP addresses.
• Fan 1, fan 2, fan 3, and fan 4 rotational speed.
• CPU temperature.
• Hard disk capacity.
• Virtual and physical memory capacity.
d. After successful POST completion, the LCD panel displays a
Welcome!! message, then continuously cycles through and
displays server operational information.
e. After rebooting the server at the LCD panel, log on to the
management server’s Windows 2000 desktop through a LAN
connection to a browser-capable PC. Refer to Access the
Management Server Desktop on page 2-55 for instructions.The
SAN management application starts and the SANavigator Log In
or EFCM Log In dialog box displays (Figure 3-18).
Boot from LAN?
Press <Enter>