FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
Diagnostics
3-39
4
POST/IPL diagnostics detected a FRU failure as indicated by event
code 400 with supplementary event data.
a. At the SANpilot event log or the Sphereon 4500 Event Log,
examine the first two bytes (0 and 1) of event data associated
with event code 400.
b. Byte 0 is a FRU code that indicates the failed component. Byte 1
is the slot number of the failed FRU (00 for a nonredundant FRU,
and 00 or 01 for redundant FRUs).
Table 3-6 lists byte 0 FRU codes and associated steps that describe
fault isolation procedures.
5
The CTP card failed POSTs (as indicated by FRU code 02). Replace
the switch. Exit MAP.
6
A fan module failed POSTs (as indicated by FRU code 05) and the
power supply containing the fan must be removed and replaced.
Refer to RRP 2: Redundant Power Supply on page 5-6.
Table 3-5 MAP 200 Event Codes
Event
Code
Explanation Action
400 Power-up diagnostic failure. Go to step 4.
411 Firmware fault. Go to step 8.
Table 3-6 MAP 200 Byte 0 FRU Codes
Byte 0 Failed FRU Action
02 CTP card. Go to step 5.
05 Fan module. Go to step 6.
06 Power supply. Go to step 7.