Diagnostics
3-37
23
At the management server’s Hardware View (Figure 3-10 on
page 3-20), does a yellow triangle appear at the alert panel and a
blinking red and yellow diamond (failed FRU indicator) appear to
overlay a power supply graphic?
NO YES
A redundant power supply failed. Go to step 8.
24
At the Hardware View, does a grey square appear at the alert panel, a
No Link status appear at the Sphereon 4500 Status table, and
graphical FRUs appear uninstalled?
YES NO
A green circle appears at the alert panel and the switch
appears operational. Exit MAP.
The grey square indicates the management server or customer-
supplied server cannot communicate with the switch because:
The switch-to-server Ethernet link failed.
AC power distribution in the switch failed, or AC power was
disconnected.
The switch CTP card failed.
Continue to the next step.
25
Ensure the switch is connected to facility AC power. Inspect the
switch for indications of being powered on, such as:
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
Go to step 13.
Analysis for an Ethernet link or a CTP failure is not described in this
MAP. Go to MAP 0000: Start MAP on page 3-6. If this is the second