FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-36
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
20
A Page cannot be found, Unable to locate the server, HTTP
404 - file not found, or other similar message appears. The message
indicates the PC cannot communicate with the switch because:
The switch-to-PC Internet link could not be established.
AC power distribution in the switch failed, or AC power was
disconnected.
The switch CTP card failed.
Continue to the next step.
21
Ensure the switch reporting the problem is connected to facility AC
power. Inspect the switch for indications of being powered on, such
as:
At the front bezel, an illuminated PWR LED (green)
or ERR LED (amber).
Illuminated LEDs adjacent to Fibre Channel ports.
Audio emanations and airflow from cooling fans.
Does the switch appear powered on?
YES NO
Go to step 13.
Analysis for an Ethernet link or a CTP failure is not described in this
MAP. Go to MAP 0000: Start MAP on page 3-6. If this is the second
time at this step, contact the next level of support. Exit MAP.
22
Inspect power supply operational states at the SANpilot interface.
a. At the View panel, click the FRU Properties tab. The View panel
(FRU Properties tab) displays.
b. Inspect the Status fields for both power supplies.
Does the Status field display a Failed message for either power
supply?
NO YES
A redundant power supply failed. Go to step 8.
The switch appears operational. Exit MAP.