FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)
3-32
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
7
Verify redundant power supply operation.
a. Inspect the power supply and ensure the amber LED is
extinguished.
b. At the management server’s Hardware View (Figure 3-10 on
page 3-20), observe the graphic representing the power supply
and ensure a failure symbol (blinking red and yellow diamond)
does not appear.
Is a failure indicated?
YES NO
↓ The switch appears operational. Exit MAP.
8
Visual inspection or an event code 200 or 201 indicates one or both
power supplies must be removed and replaced. Refer to RRP 2:
Redundant Power Supply on page 5-6.
• This procedure is concurrent and can be performed while switch
power is on.
• Perform the data collection procedure as part of FRU removal
and replacement.
• If multiple power supply failures occurred, connect the switch to
facility AC power after both power supplies are replaced.
ATTENTION ! Do not remove a power supply unless a replacement FRU is
immediately available. To avoid product overheating, a removed power
supply must be replaced within five minutes.
Did power supply replacement solve the problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.