FW 07.00.00/HAFM SW 08.06.00 McDATA Sphereon 4500 Fabric Switch Installation and Service Manual (620-000159-320, April 2005)

3-30
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
MAP 0100: Power Distribution Analysis
This MAP describes fault isolation for the switch power distribution
system, including defective AC power cords or redundant power
supplies.
1
Was an event code 200 or 201 observed at the SANpilot event log or
at the Sphereon 4500 Event Log (management server)?
YES NO
Go to step 9.
2
Table 3-4 lists event codes, brief explanations of the codes, and the
associated steps that describe fault isolation procedures.
3
Have the customer inspect and verify that facility power is within
specifications. These specifications are:
One single-phase connection for each power supply.
Input power between 100 and 240 VAC, and at least 5 amps.
Input frequency between 47 and 63 Hz.
Is facility power within specifications?
YES NO
Ask the customer to correct the facility power problem. When
facility power is corrected, continue to the next step.
Table 3-4 MAP 100 Event Codes
Event
Code
Explanation Action
200 Power supply AC voltage failure. Go to step 3.
201 Power supply DC voltage failure. Go to step 3.